Store Logo  
  Catalog » Siskiyou Mechanicals » Electrode Holders » SD-ST50-200/HS My Account  |  Cart Contents  |  Checkout   
 
Products
Perfusion Systems
Temperature Control
SmartSquirt® Microperfusion
Perfusion Chambers
Rodent Fixation Systems
Brain Slice & Tissue Chambers
Peristaltic Pumps
Amplifiers & Stimulators
MDC/Axon Instruments
Heka Data Acquisition
Siskiyou Mechanicals
  Fixed Platform
  Manual & Motorized Platforms
  Towers
  Spacers
  Manual & Motorized Translators
  Economy Manual Translator
  Manual Manipulators
  Motorized Manipulators
  Controllers & Accy.
  Hydraulic Manipulators
  Piezo Switcher
  Headstage & Pipette Holders
  Chamber Shuttle
  Perfusion Chambers
  Electrode Holders
  Pipette Puller
  Tissue Slicer
  Optogenetic Positioner
Sutter Manipulators
Micropipette Fabrication
TMC Air Tables
Filter Wheels
Automated Pipette Patch Clamping
Functionalized Bio-surfaces

View All Items
Shopping Cart
0 items
Manufacturers
 
Electrode holder fits Axon 200/700 & HS-2A amplifiers
[SD-ST50-200/HS]
$105.00

The new Stable-tip electrode holders eliminate the final instability link in the electrophysiology experimental setup. We've taken a thermally stable base material and coated it with aluminaoxide. This coating has two benefits: first, it is non-conductive so the holder does not act as an electrical antenna; second, it is very resistant to corrosion.

Under conditions of a high resistance electrode seal (gigaseal), the ST series electrode holder has a noise level of 0.79-0.80 pA RMS (5kHz filter); polycarbonate measured 0.78-0.79 pA (reported using an Axopatch 200B in whole-cell mode). The base material of the Stable-tip has a thermal expansion coefficient of 23µm/m°C versus 70µm/m°C of a polycarbonate holder. That is an improvement by a factor of three.

The Stable-tip electrode holders come with one (1) each of Ag-wires and wire seals. The universal clamp design will accommodate a range of electrode glass from 1mm-2mm.

NOTE: Pipette seals are not required for the latest model ST-50. When ordering, specify the headstage amplifier. If ordering for a Axon CV-4 the major diameter of the mounting feature is needed.

Specifications

•  High thermal stability

•  Low noise

•  Versions for BNC and threaded headstage attachment

•  Thermal expansion coefficient, CTE linear 68°:
Polycarbonate 70 µm/m-°C
Stable-tip 23 µm/m-°C

•  Electronic noise characteristics:
Polycarbonate 0.78-0.79 pA
Stable-tip 0.79-0.80 pA

For full web page, please see http://www.autom8.com/siskiyou-electrode-holder.html

Download a brochure at http://www.autom8.com/pdfs/sisikiyou/Siskiyou-Accessories.pdf